Project Overview
Client: UH Technical Services LLC
Location: Villa 100, Topanga, DAMAC Hills, Dubai, UAE.
Contact Person: Mr. Shehbaz
Start Date: 16 Jan 2024
End Date: 25 Jan 2024
Area: Rooftop of 3 3-bedroom villa (145 m2)
The task involved waterproofing the entire rooftop, including areas beneath air conditioning units and under decorative tiles.
Findings
- Multiple leaks were reported in rooms directly below the rooftop.
- Gravel and foam insulation covered the bitumen waterproofing membrane, all of which had to be removed manually.
- The membrane and tiles beneath were severely damaged and required careful handling during removal.
Solution
- Applied a UV-resistant, anti-fungal polyurethane (PU) waterproofing system membrane across the entire rooftop surface.
- The roof was mechanically ground to ensure strong bonding of the new coating.
- Special care was taken to waterproof under AC units, gravel, and tiles without damaging them.
- All pipe penetrations were sealed using highly flexible polyurethane sealant.
- A 5-year leakage warranty was provided upon successful completion.